    Our offered CMS8000 Five Parameter Patient Monitor is a conventional equipment that is used in Arrhythmia analysis and S-T segment analysis. Owing to its technically sound design and user-friendly operations, it ensures a high level of accuracy. The device is the most suitable for the adult, pediatric and neonatal patient. It is equipped with a high definition seven-leads display. CMS8000 Five Parameter Patient Monitor is electrically operated and does not require frequent maintenance to function uninterruptedly for a long period of time. 

    Specification :

    Features :

    • 12.1" Colour TF T LCD display with waveforms upto 8 Channels
    • Portable . streamline handle design
    • Monitor measures from Adult to Neonates
    • Graphic and tabular Trend for 96 hours for all parameters
    • Multi Screen format
    • Audible and Visual alarms with adjustable alarm ranges
    • Powerful data management and storage capacity
    • Manual or Automatic NIBP measuring with 500 unit memory
    • Rechargeable battery backup
    • Weight : 4.5Kg approx.

    Respiration

    • Method: RA-LL impedance
    • Measurement range: Adult: 0-12orpm. Paediatric/neonatal 0-150mm
    • Apnea alarm: YES

    Temperature :

    • Resolution: 0.1oC
    • Channel: Dual-channel
    • Measurement range: 0-50oC

    IBP (Ungradable)

    • Channel: 2 channels
    • Pressure transducer: Sensitivity: 5( mV/V/mmHg)
    • Transducer sites: ART, PA, CVP. RAP, LAP. ICP
    • Alarm range: -l0~300mmHg

    ECG

    • 5-lead or l2-lead selectable
    • Input: S-lead: RA; LA; RL; LL; V or R; L; N; F; C
    • Lead selection: l; I]; ill; avR; avL; avF; Vx; CAL
    • Gain selection:x0.25, x0.5, x1, x2,auto
    • Sweep speed: 12.5rnm/s, 25mm/s, 5omm/s
    • Accuracy: +1bpm or +1%, whichever is greater
    • Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
    • Calibration signal: lmV +5%
    • Operation modes: Diagnostic, Monitor, Surgery
    • Heart rate range: Adult: 15-300bpm Pacdiatric/ Neonatal: 15- 350bpm
    • Measurement range: -2.0mV~2.0mV
    • S-T detection: YES, Arrhythmia analysis: YES
    • Alarm: YES, audible and visual alarm, alarm events recallable

    NIBP

    • Method: Oscillometiy
    • Operation modes: Manual/Automatic."STAT
    • Measurement unit: mmHg"KPa selectable
    • Measurement types: Systolic, Diastolic. Mean
    • Measurement range: Adult: 10-270mmHg
    • Over-pressure protection: YES
    • Resolution: l mmHg
    • Accuracy : The mean error shall be less than +5 mmHg, the standard deviation shall be less than + 8 mmHg
    • Alarm: Systolic, Diastolic, Mean

    SpO2

    • Measurement range: 0-100%
    • Accuracy: +2%(70~100%); 0~69% unspecified