Our offered CMS8000 Five Parameter Patient Monitor is a conventional equipment that is used in Arrhythmia analysis and S-T segment analysis. Owing to its technically sound design and user-friendly operations, it ensures a high level of accuracy. The device is the most suitable for the adult, pediatric and neonatal patient. It is equipped with a high definition seven-leads display. CMS8000 Five Parameter Patient Monitor is electrically operated and does not require frequent maintenance to function uninterruptedly for a long period of time. 

Specification :

Features :

  • 12.1" Colour TF T LCD display with waveforms upto 8 Channels
  • Portable . streamline handle design
  • Monitor measures from Adult to Neonates
  • Graphic and tabular Trend for 96 hours for all parameters
  • Multi Screen format
  • Audible and Visual alarms with adjustable alarm ranges
  • Powerful data management and storage capacity
  • Manual or Automatic NIBP measuring with 500 unit memory
  • Rechargeable battery backup
  • Weight : 4.5Kg approx.

Respiration

  • Method: RA-LL impedance
  • Measurement range: Adult: 0-12orpm. Paediatric/neonatal 0-150mm
  • Apnea alarm: YES

Temperature :

  • Resolution: 0.1oC
  • Channel: Dual-channel
  • Measurement range: 0-50oC

IBP (Ungradable)

  • Channel: 2 channels
  • Pressure transducer: Sensitivity: 5( mV/V/mmHg)
  • Transducer sites: ART, PA, CVP. RAP, LAP. ICP
  • Alarm range: -l0~300mmHg

ECG

  • 5-lead or l2-lead selectable
  • Input: S-lead: RA; LA; RL; LL; V or R; L; N; F; C
  • Lead selection: l; I]; ill; avR; avL; avF; Vx; CAL
  • Gain selection:x0.25, x0.5, x1, x2,auto
  • Sweep speed: 12.5rnm/s, 25mm/s, 5omm/s
  • Accuracy: +1bpm or +1%, whichever is greater
  • Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
  • Calibration signal: lmV +5%
  • Operation modes: Diagnostic, Monitor, Surgery
  • Heart rate range: Adult: 15-300bpm Pacdiatric/ Neonatal: 15- 350bpm
  • Measurement range: -2.0mV~2.0mV
  • S-T detection: YES, Arrhythmia analysis: YES
  • Alarm: YES, audible and visual alarm, alarm events recallable

NIBP

  • Method: Oscillometiy
  • Operation modes: Manual/Automatic."STAT
  • Measurement unit: mmHg"KPa selectable
  • Measurement types: Systolic, Diastolic. Mean
  • Measurement range: Adult: 10-270mmHg
  • Over-pressure protection: YES
  • Resolution: l mmHg
  • Accuracy : The mean error shall be less than +5 mmHg, the standard deviation shall be less than + 8 mmHg
  • Alarm: Systolic, Diastolic, Mean

SpO2

  • Measurement range: 0-100%
  • Accuracy: +2%(70~100%); 0~69% unspecified
  • Alarm range: 0-100%